HomeBuySellDealsBrandsCategoriesSolutionsIndustriesGuidesAboutContact
Brand and category

Huawei Power Supplies Products, Prices & Part Numbers

Browse Huawei Power Supplies products by model and manufacturer part number. Check specifications, price, availability and active buyer requirements through KOMPLEKT UAE.

Huawei Power Supplies sourcing

This collection brings together 216 current Huawei Power Supplies products and 0 active buyer requirements. Compare exact identifiers and specifications, then request a current commercial offer or submit matching stock.

Popular models and part numbers

S5735-L48P4S-A1 · S5735-L · S5731-S48P4X · S5731-S24P4X · VP9630-C-8-AC · VP9630-12-AC · U291GPU01-P · TNDD8FEELE00 · TNCM000PIU00 · TN8M000PDU02 · SIG9800-X · S-1.1/LC

Huawei Power Supplies products

View all →
S5735-L48P4S-A1Huawei S5735-L48P4S-A1 Huawei S5700 Series SwitchesAvailable on request
STK-305713HuaweiPower SuppliesQty On requestAED 0.00Dubai, UAE2026-07-27
Huawei S5735-L48P4S-A1 Switch Product Overview Huawei S5735-L48P4S-A1 Switch is simplified gigabit Ethernet switch with 48x10/100/1000Base-T ports 4 x GE SFP ports AC power supply PoE+ Forwarding performance: 78 Mpps and Switching capacity: 104 Gbps/432 Gbps. The product is ideal for scenarios such as enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and the Huawei Versatile Routing Platform (VRP), Huawei Huawei S5735-L48P4S-A1 Switch supports a variety of intelligent O&M features for audio and video services, including the enhanced Media Delivery Index (eMDI). With this eDMI function, the switch can function as a monitored node to periodically conduct statistics and report audio and video service indicators to the CampusInsight platform. In this way, the CampusInsight platform can quickly demarcate audio and video service quality faults based on the results of multiple monitored nodes. Brand Huawei Model S5735-L48P4S-A1 Port 48x10/100/1000Base-T ports 4 x GE SFP ports Chassis height [U] 1 U Weight without packaging [kg(lb)] 3.23 kg (7.12 lb) Weight with packaging [kg(lb)] 4.28 kg (9.44 lb) Typical power consumption [W] 58.7 W Typical heat dissipation [BTU/hour] 200.29 BTU/hour MTBF [year] 44.9 year MTTR [hour] 2 hour Availability >0.99999 Redundant power supply Not supported Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F) Long-term operating relative humidity [RH] 5% to 95%, noncondensing Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.) Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.) Power supply mode AC built-in Maximum power consumption [W] Not providing the PoE function: 76.1 W 100% PoE loads: 456.1 W (PoE: 380 W) Maximum heat dissipation [BTU/hour] Not providing the PoE function: 259.66 100% PoE loads: 1556.26 Maximum input current [A] 6:00 AM
Memory: 512 MB Flash memory 512 MB Console port RJ45 Eth Management port Not supported USB Supported RTC Not supported RPS input Not supported Service port surge protection [kV] Common mode: ±7 kV Power supply surge protection [kV] ±6 kV in differential mode, ±6 kV in common mode Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) Short-term operating temperature [°C(°F)] -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) Types of fans Built-in Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment Airflow direction Air intake from left and front, air exhaustion from right PoE Supported Rated input voltage [V] AC input: 100 V AC to 240 V AC, 50/60 Hz High-Voltage DC input: 240 V DC Input voltage range [V] AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz High-Voltage DC input: 190 V DC to 290 V DC Certification EMC certification,Safety certification,Manufacturing certification Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)
S5735-LHuawei S5735-L Huawei S5700 Series SwitchesAvailable on request
STK-305711HuaweiPower SuppliesQty On requestAED 0.00Dubai, UAE2026-07-27
S5735-L24P4X-A1 Overview Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols - providing higher performance and more powerful service processing capabilities for networks. S5735-L24P4X-A1 Specification Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) Chassis height [U] : 1 U Typical power consumption [W] : 42.4 W Typical heat dissipation [BTU/hour] : 144.67 BTU/hour Maximum power consumption [W] : Not providing the PoE function: 53.8 W 100% PoE loads: 433.8 W (PoE: 380 W) Maximum heat dissipation [BTU/hour] : Not providing the PoE function: 183.5 100% PoE loads: 1480.17 MTBF [year : 52.74 year MTTR [hour] : 2 hour Availability : >0.99999 Noise at normal temperature (acoustic power) [dB(A)] : 50 dB(A) Noise at normal temperature (acoustic pressure) [dB(A)] : 38.2 dB(A) Number of card slots : 0 Number of power slots : 0 Number of fans modules : 2 Redundant power supply : Not supported Long-term operating temperature [°C(°F)] : -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) Short-term operating temperature [°C(°F)] : -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. Storage temperature [°C(°F)] : -40°C to +70°C (-40°F to +158°F) Long-term operating relative humidity [RH] : 5% to 95%, noncondensing Long-term operating altitude [m(ft.)] : 0-5000 m (0-16404 ft.) Storage altitude [m(ft.)] : 0-5000 m (0-16404 ft.) Power supply mode : AC built-in Rated input voltage [V] : AC input: 100 V AC to 240 V AC, 50/60 Hz,High-Voltage DC input: 240 V DC, Input voltage range [V] : AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz,High-Voltage DC input: 190 V DC to 290 V DC, Maximum input current [A] : 6 A Memory : 512 MB Flash memory : 512 MB Console port : RJ45 Eth Management port : Not supported USB : Supported RTC : Not supported RPS input : Not supported Service port surge protection [kV] : 98011318:,Common mode: ±7 kV,98011318-001:,Common mode: ±2 kV Power supply surge protection [kV] : ±6 kV in differential mode, ±6 kV in common mode Types of fans : Built-in Heat dissipation mode : Heat dissipation with fan, intelligent fan speed adjustment Airflow direction : Air intake from left and front, air exhaustion from right PoE : Supported Certification : EMC certificatio, Safety certification,Manufacturing certification
S5731-S48P4XHuawei S5731-S48P4X Specification Fixed port : 48 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports Dimensions (W x D x H) : 442 mm x 420 mm x 43.6 mm Chassis height : 1 U Chassis weight (includinAvailable on request
STK-305708HuaweiPower SuppliesQty On requestAED 0.00Dubai, UAE2026-07-27
S5731-S48P4X Specification Fixed port : 48 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports Dimensions (W x D x H) : 442 mm x 420 mm x 43.6 mm Chassis height : 1 U Chassis weight (including packaging) : 8.8 kg Power supply type : 1000 W PoE AC (pluggable) Rated voltage range : AC input (1000 W AC PoE): 100 V AC to 240 V AC, 50/60 Hz Maximum voltage range • AC input (1000 W AC PoE): 90 V AC to 290 V AC, 45 Hz to 65 Hz • High-voltage DC input (1000 W AC PoE): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) Maximum power consumption • 132 W (without PD) • 1750 W (with PD, PD power consumption of 1440 W) Noise • Under normal temperature (sound power): 62.3dB (A) • Under high temperature (sound power): 71.8dB (A) • Under normal temperature (sound pressure): 52.8dB (A) Operating temperature • 0-1800 m altitude: -5°C to +45°C • 1800-5000 m altitude: The operating temperature reduces by 1oC every time the altitude increases by 220 m. Storage temperature : -40°C to +70°C Relative humidity : 5% to 95% (non-condensing) Surge protection specification (service port) : Common mode: ±6 kV Surge protection specification (power port) • Differential mode: ±6 kV • Common mode: ±6 kV Heat dissipation : Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans MAC address table IEEE 802.1d standards compliance 32K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses VLAN 4094 VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports VLAN mapping Ethernet loop protection RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching SEP ERPS (G.8032) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy Up to 16K FIBv4 entries Up to 8K FIBv4 entries Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP IPv6 features Up to 8K ND entries PMTU IPv6 Ping, IPv6 Tracert, and IPv6 Telnet ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery snooping (MLDv1/v2) IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN Multicast IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN QoS/ACL Rate limiting in the inbound and outbound directions of a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues per port DRR, SP and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p and DSCP fields of packets Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Queue-based rate limiting and shaping on ports Security Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH V2.0 HTTPS CPU protection Blacklist and whitelist Attack sour
S5731-S24P4XHuawei S5731-S24P4X Specification Fixed port : 24 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports Dimensions (W x D x H) : 442 mm x 420 mm x 43.6 mm Chassis height : 1 U Chassis weight (includinAvailable on request
STK-305707HuaweiPower SuppliesQty On requestAED 0.00Dubai, UAE2026-07-27
S5731-S24P4X Specification Fixed port : 24 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports Dimensions (W x D x H) : 442 mm x 420 mm x 43.6 mm Chassis height : 1 U Chassis weight (including packaging) : 8.6 kg Power supply type : 1000 W PoE AC (pluggable) Rated voltage range : AC input (1000 W AC PoE): 100 V AC to 240 V AC, 50/60 Hz Maximum voltage range • AC input (1000 W AC PoE): 90 V AC to 290 V AC, 45 Hz to 65 Hz • High-voltage DC input (1000 W AC PoE): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) Maximum power consumption • 121 W (without PD) • 977 W (with PD, PD power consumption of 720 W) Noise •Under normal temperature (sound power): 62.3dB (A) • Under high temperature (sound power): 71.8dB (A) • Under normal temperature (sound pressure): 52.8dB (A) Operating temperature • 0-1800 m altitude: -5°C to +45°C • 1800-5000 m altitude: The operating temperature reduces by 1oC every time the altitude increases by 220 m. Storage temperature : -40°C to +70°C Relative humidity : 5% to 95% (non-condensing) Surge protection specification (service port) : Common mode: ±6 kV Surge protection specification (power port) • Differential mode: ±6 kV • Common mode: ±6 kV Heat dissipation Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans MAC address table IEEE 802.1d standards compliance 32K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses VLAN 4094 VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports VLAN mapping Ethernet loop protection RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching SEP ERPS (G.8032) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy Up to 16K FIBv4 entries Up to 8K FIBv4 entries Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP IPv6 features Up to 8K ND entries PMTU IPv6 Ping, IPv6 Tracert, and IPv6 Telnet ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery snooping (MLDv1/v2) IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN Multicast IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN QoS/ACL Rate limiting in the inbound and outbound directions of a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues per port DRR, SP and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p and DSCP fields of packets Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN IDQueue-based rate limiting and shaping on ports Security Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH V2.0 HTTPS CP
WhatsApp